Washing machine - How to replace the ventilator (1)
Issue
How to replace the ventilator
Applies to
- Washing machine
Resolution

Refer always to your product’s user manual safety information before any repair or maintenance operation. https://www.electrolux.com/support/user-manuals/

WARNING! RISK OF ELECTRIC SHOCK
Before any repair or maintenance operation, deactivate the appliance and disconnect the mains plug from the socket.


WARNING! RISK OF INJURY

Always take care when moving appliances. For heavy appliances it's safest for two persons to move it. Always use safety gloves and safety footwear. Wear safety gloves at all times to protect from cuts from sharp edges.

WARNING! RISK OF EYE INJURY

Wear safety glasses if you perform maintenance or repair work involving springs.

WARNING! RISK OF PINCHING

Wear safety glovesif you perform maintenance or repair work involving belts.

WARNING! CHOKING HAZARD
Small parts not for children under 3 years. Keep all small parts and packaging out of reach of children.
Only adults should use or install the product.
Before any maintenance operation, turn off water supply to the appliance. Always empty the appliance of all the water. Any maintenance should be carried out with the appliance standing upright. Residual water could damage electronics if the appliance is placed on any of its sides.
Make sure to use the product only for its designated purpose and verify that it is a compatible part for the intended product.
Do not use or install the product if damaged.
Please note that self-repair or nonprofessional repair can have safety consequences if not done properly and might void the warranty. Possessing the necessary know-how is essential.
HOW TO REPLACE VENTILATOR
1. Unscrew the two 8mm screws on the back of the washing machine lid and slide back to release.



2. Unscrew the four 7mm screws on the air duct and the 8mm screw on the right of the ventilator.


3. Lever out the air duct tub from the cross bar and pull the air duct away to the left to release from the ventilator.


4. Lift the ventilator away from the condenser and the condenser hose. NOTE: Ensure that the ventilator is correctly positioned back into the condenser during refitting.

5. Carefully disconnect the wiring connectors from the fan motor. NOTE: Ensure that the connectors are correctly refitted during reinstallation. Be careful not to damage the wiring connectors.

6. Unscrew the three 8mm screws holding the ventilator to the fan motor and then pull the fan motor away to release.


7. Remove the seal from the ventilator and transfer to the new ventilator.


19. When assembling, repeat steps in reverse order.